Our Portfolio

Woldingham Tower

B&W Consultants Ltd were given the tower analysis, design and detailing for an antenna that was to be mounted on the top of an existing 39.6m high lattice structure at Woldingham.

After a measured structural climb survey was carried out the results were analysised in MSTower to BS8100 standards. The tower proved to be over stressed and required extensive strengthening works.

Strengthening drawings were then produced along with the new interface steelwork for the new top mounted antenna.